Magnet

  • AVHD400 (KAIST)
    • Installed : 2013
    • Bruker AVANCE  III HD Nanobay (9.4 T)
    • Software :Topspin 3.6.5 on CentOS
      • until 2022.07.14 // Topspin 3.6.3
      • until 2021.10.01 // Topspin 3.5.7
    • Nucleus : 1H,13C,19F,31P, etc…
    • Temperature : -40C ~ 80 C (usual)// -100C ~ 120C(need permission)
    • Probe : iProbe HR Liquids
      • 1H S/N ~ 592.8 (2022.08.30)
      • 13C S/N ~ 298.0 (2022.08.30)
        • uniil 2022.08.30 : BBFO 400Mhz S1 5mm with z-gradient PLUS
          • 1H S/N ~ 260.31, 13C S/N ~ 199.29
  • AS400 (KAIST)
    • Installed : 2018
    • Bruker AVANCE  III HD (9.4 T)
    • Software : Topspin 3.6.5 on CentOS
      • until 2022.07.12 // Topspin 3.6.3
      • until 2021.10.21 // Topspin 3.5.7
    • Nucleus : BBFO probe : 1H,13C,19F,31P, etc…
    • Temperature : 25C (usual) // 25 ~ 80C(need permission)
    • Probe : BBFO 400Mhz S1 5mm with z-gradient
      • 1H S/N  ~ 553.5 : 1 (2022.02.22)
      • 13C S/N ~ 293.1 : 1 (2022.02.22)
        • during 2021.10.21 ~ 2022.02.22 // DUL 400Mhz SB 5mm with z-gradient
      • 24 slots Automatic Sample Handler
  • AVNEO400 (KAIST)
    • Installed : 2021
    • Bruker AVANCE  NEO Nanobay (9.4 T)
    • Software : Topspin 4.1.4 on CentOS
      • until 2022.07.12 // Topspin 4.1.4.
    • Nucleus : 1H,13C,19F,31P, etc…
    • Temperature : 25C (usual) // 25 ~ 80 C (need permission)
    • Probe : iProbe HR Liquids
      • 1H S/N ~ 565.8 : 1 (2021.11.04)
      • 13C S/N ~ 321.0 : 1 (2021.11.04)
  • AV500 (KAIST)
    • Installed : 2020
    • Bruker AVANCE  NEO (11.74 T)
    • Software : Topspin 4.1.4 on CentOS
      • until 2022.07.07 // Topspin 4.1.3
      • until 2021.12.12 // Topspin 4.1.1
    • Nucleus : 1H,13C,19F,31P, etc…
    • Temperature : 25C (usual)
      • -35~80C (short exp. need permission)
      • -90 C ~ 120C(long exp. for request or when monitoring by NMR manager)
    • Probe : iProbe HR Liquids
      • 1H S/N ~ 995.3 (2023.11.08)
      • 13C S/N ~ 428.9 (2023.11.08)
        • Until 2023.11.07 // 1H S/N ~ 924.3, 13C S/N ~ 396.4
      • 24 slots Automatic Sample Handler
  • IBS600 (IBS)
    • Installed : 2013
    • Agilent DD-2 (14.1 T)
    • Software : openVNMRJ 2.1A on CentOS
    • Nucleus : 1H,13C,19F,31P, etc…
    • Temperature : Room Temperature
    • Probe : 5mm PFG OneNMR Probe-PT G5157B
      • 1H S/N ~ 1413.45 : 1 (2020.09.17)
      • 13C S/N ~ 203.23 : 1 (2020.09.17)
    • 96 slots Automatic Sample Handler
  • Solid400 (KAIST)
    • Service start from : 2024
      • installed 2014 as IBS equipment and transferred 2024
    • Bruker AVANCE HD III WideBore
    • Software : Topspin 3.6.4 on Windows
    • Nucleus : 1H, 13C, 31P, 27Al …
    • Temperature : Room temperature // -90 ~ 120C (need permission)
    • Probe 1 : 3Ch HXY probe
      • Variable Temperature Experiments
    • Probe 2 : 2Ch HX probe
    • CP-MAS available . (no HR-MAS)

 

 

_____________________________________________________________________

  • AV400 (Decommisioned)
    • Decommissioned : 2021.10.28
    • Installed : 1998
    • Bruker AVANCE  400 (9.4 T)
    • Software : Topspin 1.3 on CentOS (w/o topshim)
    • Nucleus : 1H, 13C
    • Temperature : Room Temperature
    • Probe : DUL 400Mhz SB 5mm with z-gradient
      • 1H S/N ~ 187.51 : 1 (2020.06.30)
      • 13C S/N ~ 83.88 : 1 (2020.06.30)
  • AV300 (Decommisioned)
    • Decomminssioned : 2021.09.01
    • Installed : 2000
    • Bruker AVANCE  300 (7.0 T)
    • Software : Topspin 1.3 on CentOS (w/o topshim)
    • Nucleus : 1H only (no 13C)
    • Temperature : Room Temperature
    • Probe : BBI probe (from 2021.02.03)
      • BBI 300Mhz
        • 1H S/N ~ 149.8 : 1 (2021.02.03)
      • QNP 300Mhz SB 5mm
        • 1H S/N ~ 129.26 : 1 (2020.06.30)